Retrofit Vapour Control Layer
Advantages
- Airtightness installed from the outside
- Specifically developed for roof restoration
- Humidity-variable MVTR
- No additional airtight joints required at the rafters
- High tear resistance due to fleece reinforcement
Areas of application
DASATOP® is an air-resistive barrier for installation over rafters and across sarking in roof renovation projects. Installed from the outside, DASATOP® protects structures from rain wetting during construction while cladding is removed.
Technical specs
Material | |||
Protective and covering fleece | Polypropylene | ||
Functional film | Polyethylene copolymer | ||
Property | Regulation | Value | Regulation |
Colour | Green | ||
Surface weight | EN 1849-2 | 100 g/m² | EN 1849-2 |
Thickness | EN 1849-2 | 0,25 mm | EN 1849-2 |
Water vapour resistance factor µ | EN 1931 | 6 400 | EN 1931 |
sd-value | EN 1931 | 1.60 m | EN 1931 |
sd value, humidity-variable | EN ISO 12572 | 0.05 - 2 m | EN ISO 12572 |
UV stability and outdoor exposure | 4 weeks | ||
Watertightness to liquid water | EN 1928 | W1 | EN 1928 |
Water column | EN ISO 811 | > 1 500 mm | EN ISO 811 |
Airtightness | EN 12114 | Tested | EN 12114 |
Tensile strength MD/LD | EN 12311-2 | 195 N/5 cm / 105 N/5 cm | EN 12311-2 |
Elongation MD/LD | EN 12311-2 | 90% / 90% | EN 12311-2 |
Nail tear resistance MD/LD | EN 12310-1 | 110 N / 105 N | EN 12310-1 |
Durability after artificial ageing | EN 1296 / EN 1931 | Passed | EN 1296 / EN 1931 |
Temperature resistance | EN 1109, EN 1296, EN 1297 | Permanent -40 °C to 80 °C | EN 1109, EN 1296, EN 1297 |